In case an irrigation event fails to cease:

  1. In the "Control Panel" section of Plantarray Client, verify that the valves open and close properly through manual operation.
  2. Check if there is a physical disturbance to the operation of the valve:
    1. Disconnect the controller from power, communication, and water.
    2. Use a manual or electric screwdriver to unscrew the 4 screws of the controller box circled below:

    3. Inside the controller box you will find the two valves wired to the PIU card as pictured below:
    4. Disconnect the valve from the PIU card.
    5. Open the valve mechanism by turning it and pull out the magnet with the spring.
    6. Check if there is anything that requires cleaning:
    7. Close the controller box, connect it back to power, communication and water, and check if the problem is solved.
  3. If the problem persists, please contact us.