If a controller is not active:
- Make sure that the power cable between the controller and the one preceding it is properly connected.
- Reset power for the entire system.
- Replace the power cable between the controller and the one preceding it.
- Replace the fuse on the PIU of the controller:
- Disconnect the controller from power, communication, and water.
- Use a manual or electric screwdriver to unscrew the 4 screws of the controller box circled below:
- Inside the controller box you will find the PIU card and the two valves as pictured below:
- The fuse is located on the bottom left corner of the PIU, as shown below:
- Use a narrow flat head screwdriver or suitable tweezers (not very sharp) to pull out the fuse from its slot:
- Place the new fuse in the slot and close the controller box.
- If the problem persists, please contact us.